YOUR DEFAULT CURRENCY IS

LCD EWP & FAN CONTROLLER (12 & 24V) PART NO: 8001

For optimum control of Davies, Craig 12 Volt and 24 Volt Electric Water Pumps.
Suits EWP®80, EWP®115, EWP®130, EWP®150, Thermatic® / Electric Fans and billeted style Electric Water Pumps.


The LCD EWP®/Fan Digital Controller has two specific functions.
This unique Digital Controller will manage the operation of the EWP® by varying the speed of the pump in response to the coolant temperature and manage control of your electric engine fan.

The Controller has a push-button to lock in any temperature from 60°C (140°F) to 100°C (212°F). It’s recommended you set/target the Controller to closely match your engine’s existing thermostat temperature.
The Digital Controller will operate the engine’s electric fan automatically once the engine has reached +3°C (+5.4°F) above the targeted / set temperature. Another significant benefit is that the Controller allows the EWP® & Fan to run on after ignition shutdown for either 3 minutes or -10°C (-14°F) of set set / target temperature to eliminate heat soak.

 

EWP, Fan & LCD Controller Installation                                                                                LCD Controller Wiring Instructions

                            

    

KIT CONTENTS

ITEM

DESCRIPTION 

QUANTITY 

1

EWP Digital Controller Assembly  

1

2

Wiring Harness (includes 10AMP fuse) 

1

3

Temp Sensor 1/4 NPT

1

4

In-Line Adaptor

1

5

Hose Clamps

2

6

Ring Terminal

1

7

Rubber Sleeves

2

8

Velcro

2

9

Instructions

1

10

Sensor Instructions

1

Technical Specifications
Technical Specification - LCD Controller
Voltage range 12V DC to 29V DC
Display LCD size 70mm (2.76”) x 60mm (2.36”)
Maximum current 12Amps
Warning alarm High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit
Targeted (set) temperatures Singular degrees from:
60°C (140°F) to 100°C (212°F)
Memory Set & targeted temperature
Fan cut-in temp. 3°C (5.4°F) above the targeted (set) temperature
Controller type PCB with micro-processor
Sensor type Thermister in housing
Overrun/ shutdown -10°C (14°F) below set/target temperature or 3 minutes
Indicators Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm)
Weight 100 grams (3.5 oz)
Dimensions

Length = 95mm (3.7")

Width = 130mm (5.1")

Depth = 25mm (1”)

   

This LCD EWP® / Fan Digital Controller (Part #8001) is Australian designed and as part of this Australian manufacturing company’s continuous improvement program this advanced Digital Controller boasts a suite of enhancements.

  

The updated LCD Digital Controller how has two specific functions. This unique Controller will now manage the operation of the EWP® by varying the speed of the EWP® in response to the temperature of the engine and manage control of your electric engine fan. The Controller has a push-button on the facia panel that offers target temperatures Singular degrees from 60°C (140°F) to 100°C (212°F).

Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The LCD Digital Controller will now operate the engine’s electric fan automatically once the engine has reached +3c above the target temperature. A significant benefit too is the Controller allows the EWP® to run on after ignition shutdown to reduce heat soak. It is recommended that engine operational temperatures be checked with manufacturer.
 

Features
null  Black & White Numerical Screen

null Celsius or Fahrenheit display option
null Warning Alarms: 

- Plus 10°C (14°F) set/target temperature
- Under temp 40°C after 5 mins
- Temp sensor error
- Over or under voltage
- EWP error

 null  Select any set temp range from 60°C (140°F)to 100°C (212°F)
null Set / targeted temperature memory
null Override feature to assist bleeding EWP & fail safe
null Input voltage display
null Compatible with billeted style Electric Water Pumps

 

 

Product Selection Guide

Application Pump Model Pump Kit Pump Combo Controller / Switch
Part #
12 V
Part #
24 V
Part#
12 V
Part #
24 V
Part #
12 V
Part #
24 V
Motorbike up to 500cc (Standard) EBP®15 9001       0444 or 0455  
Motorbike 500cc - 1000cc (Std) EBP®23 9050       0444 or 0455  
Motorbike 1000cc - 2000cc (Std) EBP®25 9005       0444 or 0455  
Vehicle Heater System (Standard) EBP®23 9050       0444 or 0455  
LPG (Butane) System (Standard) EBP®23 9050       0444 or 0455  
Intercooler
(depending on capacity)
EBP®23 9050          
EBP®25 9005          
EBP®40 9040 9041     0444 or 0455 0444 or 0455
EWP®80 8005   8907      
Engines up to 2.0L (Standard) EWP®80 8005   8907   8001 8001
Engines up to 2.0L - 3.5L (Standard) EWP®115 8025 or
8040
8026 or
8041
8930 or
8950
8931 or
8951
8001 8001
Engines up to 3.5L - 5.0L (Standard) EWP®130 8080 8081 8990 8991 8001 8001
Engines 5.0L or greater (Standard) EWP®150 8060 8061 8970 8971 8001 8001
Modified Engines
Supercharged/Turbo
EWP®150 8060 8061 8970 8971 8001 8001
Drag Racing, Drifting & Speedway EWP®150 8060 8061 8970 8971 8001 8001
Off Road / 4WDs EWP®130 8080 8081 8990 8991 8001 8001
Solar Hot Water Systems (depending on size) EBP®15 9001       0444 or 0455  
EBP®23 9050       0444 or 0455  
EBP®25 9005       0444 or 0455  
EBP®40 9040 9041     0444 or 0455 0444 or 0455

  