YOUR DEFAULT CURRENCY IS

THERMATIC® FAN SWITCH KIT (GAUGE) STREAMLINE

(Part #0501)

This is a streamline version of part number #0500 with only essential components.

A bright, attractive, compact high visibility 52mm round gauge with LED digital display for mounting in the driver’s compartment!

Automatically activates single or twin fans or a fan and Electric Water Pump at your set / targeted temperature when extra cooling is required. It can also detect transmission fluid temperature.

It senses air temperature as it passes through the radiator with the sensor placed in the radiator fin section or alternatively the sensor can also be placed directly into the coolant system in combination with a Temperature Sensor Adaptor Kit (Part 0409).

Sensor Wire Length: 380cm

 

KIT CONTENTS
DESCRIPTION UNITS
Digital Thermatic Fan Switch - 52mm Gauge 1
Gauge Stand - Mounting Screws & Pad 1
Digital Gauge Thermatic Fan Switch - Wiring Loom & Probe Sensor 1
Red 6mm Ring Terminal 1
Screw - Self Tapping 8X3/8 1
Temperature Probe Sensor Mounting Kit 1
Installation Instructions 1

 

24 VOLT APPLICATION

Kit sold in 12-volt configuration, for 24-volt application, you will need to purchase 2 x 24-volt relays.

Simply search for part 10534 in our search bar (Top Right)

 

AIR TEMPERATURE APPLICATION

The kit is set up for air temperature sensor application. For water / coolant applications, please read below.

It senses air temperature as it passes through the radiator and has an adjustable temperature range of 5ºC to 110ºC (41ºF to 230ºF).
The Temperature Sensor is placed in the radiator fin section as close to the hot coolant inlet as possible, no need to cut hoses or can be placed directly into the coolant system.

WATER / COOLANT APPLICATION
The sensor can also be placed directly into the coolant system. 

  • Use #0465 for OE style 1/4 “NPT port install
  • Use #0409 for radiator hose install

 

MOUNTING

The Thermatic® Fan Switch Kit (Gauge) must be mounted inside the vehicle’s driving compartment for easy reading and quick adjustment.

  • Convenient push-button control allows you to accurately set/target temperature for automatic activation of the Thermatic® Fan #1 and Fan #2 at independent temperatures when extra cooling is required.
  • Simple, do-it-yourself installation instructions.
  • This flexible switch can also be used to activate an Electric Water Pump and/or an Electric Booster Pump.

 

FEATURES

  • Temperature Sensor Display Range 0oC ~ 130oC (32F ~ 266F)
  • Temperature Sensor Setting Range 5oC ~ 110oC (41F ~ 230F)
  • Temperature Units interchangeable between oC & oF
  • 12V and *24V compatible
  • *For 24 Volt application: 2 x 24V Relays required, sold separately (Part #10534)
  • Can detect ambient temperature (air) as standard
  • Can detect coolant temperature
    • Use #0465 for OE style 1/4 “NPT port install
    • Use #0409 for radiator hose install
  • Can detect transmission fluid temperature
    • Use #0465 and requires (sourced externally)
      • 1 x Female Fitting Pipe Tee 1/4' NPT
      • 2 X 3/8' Barb Fitting To 1/4' NPT
  • Independent set temperature for Fan 1 and Fan 2
  • Independent control of A/C override (fan 1, fan 2 or both)
    • Can be used as manual override
  • Can Manually turn off Fans (press and hold Fan + A/C)
    • For river crossing as example
  • Led indicators for Fan1, Fan2 and A/C
    • LED lights show operating condition
    • See table below
  • Over temperature warning with audible alarm
    • See functions table below
  • Audible alarm has 5min Snooze function.
  • Universal 52mm gauge design.
  • Built in display dimmer with headlight trigger
  • Extra-long temperature sensor wires 380 cm
  • Interchangeable/replicable sensor

Fan & EWP® Switch / Controller Range

Specs
Part #0444 Part #0401 Part #0500 Part #0555 Part #0550 Part #8002
Sales Variation

#0445, #0448

#0435, #0438

#0400, #0404 #0501 #0556 #0551 #8102
Operating Voltage 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt
Maximum Current 40 Amps  20 Amps 40 Amps  40 Amps  N/A 12 Amps EWP Only
Fan Application MAX 30A Each  Relay Switching Current MAX 15A All DCPL Fans, EWPs & EBPs All brushed DCPL Fans, EWPs  All Brushless DCPL Fans, EWPs  All DCPL Fans, EWPs 
Speed Single Speed Single Speed Single Speed Variable Speed  Variable Speed  Single speed Fan & Variable EWP  
Single Fan Control null null null Brushed FAN only Brushless FAN only null
Duel Fan Control null  Wiring Dependant null Brushled FANs only Brushless FANs only Wiring Dependant
EWP control ON / OFF ONLY (USE 8002) ON / OFF ONLY (USE 8002) ON / OFF ONLY (USE 8002) Brushed EWPs only Brushless EWPs only null
EBP control ON / OFF ONLY  ON / OFF ONLY  ON / OFF ONLY  null null null
EWP/EBP and Fan control null  Wiring Dependant null null null EWP and Fans only
Duel Fan Start-Up Delay 10 Seconds null Independent set Temperature 4 independent Operating modes  5 independent Operating modes  null
Manual Override - Turn On null use #0404 Selectable Fan Override 2 Fan Override Wires 2 Fan Override Wires null
Manual Override - Turn off null null null 2 Fan Override Wires 2 Fan Override Wires null
Manual Override - Voltage Selection null null null null null null
°C D °F Change null No temperature units null null null null
Temperature Setting Range 40°C To 110°C (104°F To 230°F) 40°C To 100°C (104°F To 212°F) 5°C To 110°C (41°F To 230°F) 5°C To 110°C (41°F To 230°F) 5°C To 110°C (41°F To 230°F) 40°C To 110°C (104°F To 230°F)
Temperature Setting Method Push Button Turn Knob Push Button Push Button Push Button Push Button
Coolant Temperature Detection Requires #0409 or #0465 null Requires #0409 or #0465 null null null
Air Temperature Detection null null null null null null
Transmission Temperature Detection Ambient temperature only null Fluid measurment Requires #0465 null null null
Display Type Led Segment  null Led Segment  Led Segment + Status LEDs Led Segment + Status LEDs Black and white LCD
Temperature Display null null null null null null
Sensor Fault Display null null null null null null
Fan Operation Indicator null null null null null EWP and Fan
Over Temperature Warning null null null null null null
Audible alarm null null null null null null
Display dimmer null null null null null null
 Mounting position Engine bay Engine bay Vehicle Cabin  Engine bay Engine bay Vehicle Cabin
 Mounting options Built in Mounting holes Bracket supplied Universal 52mm gauge Built in Mounting holes Built in Mounting holes Verious Mounting Options supplied

 