YOUR DEFAULT CURRENCY IS

Variable Speed Controller Thermatic® Fan & EWP with 1/4" NPT Thermal Sensor (Part #0555)

High-performance Controller designed to optimise thermal management in automotive, industrial, marine and EV applications. It provides intelligent, precise control of either dual Thermatic® Electric Fans or Electric Water Pumps (EWP®), ensuring maximum, efficiency, system protection and reliable operation in the most demanding environments.    

The #0555 and #0556 can be used with a combination of brushed electric fans so long as the combined current draw does not exceed 40A for each of the 2 fan channel. When using multiple fans on a single fan channel we recommend only having a maximum Combined current of 30A to 35A.

 

Key Features

Flexible operating modes

  • Four distinct control strategies to suit differing cooling system applications
  • 12 & 24 Volt Applicable

Independent dual outputs

  • Two fully isolated 40A channels allow for separate control of any combination of both fan/s and/or EWP®
  • Multiple fans or pumps can be wired to a single channel, provided the combined current does not exceed 40A.
  • The recommended maximum combined current draw is 30A-35A.
  • Unique setpoints, and operating modes can be applied to each output independently.

Shutdown control

  • After ignition-off, the Controller will keep fans running for user-defined time or until defined shutdown time is reached to prevent heat-soak.

Manual overrides

  • Dedicated ON/OFF control per channel by passes automatic control if required
  • Configurable polarity accommodates different wiring and switch arrangements

Safety & failsafe options

  • In the event of Sensor fault, outputs default to full speed to protect the system

Advanced Configuration options

  • Temperature difference – defines ramping start relative to base set point
  • Defines the speed at which the fan will start
  • Shutdown time & temperature – controls post-ignition cooldown time & temperature
  • Temperature offset – Adjusts for Sensor calibration
  • Factory Reset – restores all parameters to default settings

Rugged, reliable design

  • IP67 waterproof rating ensures durability in harsh conditions

Kit Overview

This kit includes two sensors, providing flexible installation options for coolant temperature monitoring.

Sensor 1: Temperature Probe (Ambient core temperature or Coolant Fitment)

This versatile probe can detect the Ambient core temperature of the radiator core when positioned within the radiator’s fin section. Alternatively, it can be fitted directly into the coolant system using a Temperature Sensor Adaptor Kit (Part 0409 or Part 0408), available from our store.

Sensor 2: ¼ NPT Thermal Sensor Kit (Coolant or Oil Fitment)

The ¼ NPT Thermal Sensor is designed for installation directly into the fluid. The sensor can be installed into a threaded port in the thermostat housing, engine block, or directly into the radiator tank. If preferred, it can be installed into the top radiator hose using the Temperature Sensor Adaptor Kit (Part 0419 or Part 0416), the sensor can also be installed into the Transmission hose using the Transmission Temp Gauge 1/4" NPT Sensor Adapter (Part 1007), available separately from our store.

Optional Sensor: M12 x 1.5 Thermal Sensor (Coolant or Oil Fitment)

The provided sensors can be upgraded to a M12 x 1.5 Thermal sensor (Part 0462). This upgraded sensor allows you to use existing spare sensor ports in the cooling system, available separately from our store.

 

KIT CONTENTS

DESCRIPTION

UNITS

Variable speed fan controller

1

Mounting Kit - suit Thermal Sensor Probe 1
Thermal Sensor Probe 1
Sensor Thermal - coolant  temp - ¼" NPT thread 1
Yellow - 6mm Ring Terminal 2
Yellow - Wire Joiner 4
RED -  3.5mm Fork Crimp Terminal 4
Instructions 1

 

SPECIFICATIONS

Part #0555

Operating Voltage

12 & 24 Volt

Maximum Current

N/A

Fan Application

All Brushed DCPL Fans, EWPs

Speed

Variable Speed

Single Fan Control

Brushed FAN only

Duel Fan Control

Brushed FANs only

EWP control

Brushed EWPs only

EBP control

EWP/EBP and Fan control

Duel Fan Start-Up Delay

4 independent Operating modes

Manual Override - Turn On

2 Fan Override Wires

Manual Override - Turn off

2 Fan Override Wires

Manual Override - Voltage Selection

°C D °F Change

Temperature Setting Range

5°C To 110°C (41°F To 230°F)

Temperature Setting Method

Push Button

Coolant Temperature Detection

Air Temperature Detection

Transmission Temperature Detection

Display Type

Led Segment + Status LEDs

Temperature Display

Sensor Fault Display

Fan Operation Indicator

Over Temperature Warning

Audible alarm

Display dimmer

 Mounting position

Engine bay

 Mounting options

Built in Mounting holes

Accessories

Part #0578

Part #0409

Part #0422 (Duel Fan Only)

Part #0465

 


Accessories

  • Part # 0408 - Temperature Sensor Adaptor Kit - 38mm Inline Adapter
  • Part # 0409 - Temperature Sensor Adaptor Kit - 35mm Inline Adapter
  • Part # 0415 - Air bleed 35mm Adapter Kit
  • Part # 0416 - 38mm Inline Adapter with 2 x 1/4" NPT & 1 x Bung
  • Part # 0417 - Air bleed 38mm Adapter Kit
  • Part # 0418 - Compression Fitting 1/4"NPT
  • Part # 0419 - 35mm Inline Adapter with 2 x 1/4" NPT & 1 x Bung
  • Part # 1007 - Transmission Temp Gauge 1/4" NPT Sensor Adapter 3/8"

Sensor Upgrade Kits

  • Part # 0462 - M12 x 1.5 Thermal Sensor Upgrade Kit
  • Part # 0465 - ¼" NPT Thermal Sensor Upgrade Kit
  • Part # 0468 - 1/8" NPT Thermal Sensor Upgrade Kit

Spare Parts

  • Part # 0579 - Quick Fit Kit - suit Fans Trans Coolers
  • Part # 10211 - Mounting Kit - suit Thermal Sensor Probe
  • Part # 10460 - Thermal Sensor Probe
  • Part # 10465 - Sensor Connector for ¼ & 1/8 NPT Thermal Sensor
  • Part # 18415 - Sensor Thermal - coolant temp - ¼" NPT thread

Fan & EWP® Switch / Controller Range

Specs
Part #0444 Part #0401 Part #0500 Part #0555 Part #0550 Part #8002
Sales Variation

#0445, #0448

#0435, #0438

#0400, #0404 #0501 #0556 #0551 #8102
Operating Voltage 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt 12 & 24 Volt
Maximum Current 40 Amps  20 Amps 40 Amps  40 Amps  N/A 12 Amps EWP Only
Fan Application MAX 30A Each  Relay Switching Current MAX 15A All DCPL Fans, EWPs & EBPs All brushed DCPL Fans, EWPs  All Brushless DCPL Fans, EWPs  All DCPL Fans, EWPs 
Speed Single Speed Single Speed Single Speed Variable Speed  Variable Speed  Single speed Fan & Variable EWP  
Single Fan Control null null null Brushed FAN only Brushless FAN only null
Duel Fan Control null  Wiring Dependant null Brushled FANs only Brushless FANs only Wiring Dependant
EWP control ON / OFF ONLY (USE 8002) ON / OFF ONLY (USE 8002) ON / OFF ONLY (USE 8002) Brushed EWPs only Brushless EWPs only null
EBP control ON / OFF ONLY  ON / OFF ONLY  ON / OFF ONLY  null null null
EWP/EBP and Fan control null  Wiring Dependant null null null EWP and Fans only
Duel Fan Start-Up Delay 10 Seconds null Independent set Temperature 4 independent Operating modes  5 independent Operating modes  null
Manual Override - Turn On null use #0404 Selectable Fan Override 2 Fan Override Wires 2 Fan Override Wires null
Manual Override - Turn off null null null 2 Fan Override Wires 2 Fan Override Wires null
Manual Override - Voltage Selection null null null null null null
°C D °F Change null No temperature units null null null null
Temperature Setting Range 40°C To 110°C (104°F To 230°F) 40°C To 100°C (104°F To 212°F) 5°C To 110°C (41°F To 230°F) 5°C To 110°C (41°F To 230°F) 5°C To 110°C (41°F To 230°F) 40°C To 110°C (104°F To 230°F)
Temperature Setting Method Push Button Turn Knob Push Button Push Button Push Button Push Button
Coolant Temperature Detection Requires #0409 or #0465 null Requires #0409 or #0465 null null null
Air Temperature Detection null null null null null null
Transmission Temperature Detection Ambient temperature only null Fluid measurment Requires #0465 null null null
Display Type Led Segment  null Led Segment  Led Segment + Status LEDs Led Segment + Status LEDs Black and white LCD
Temperature Display null null null null null null
Sensor Fault Display null null null null null null
Fan Operation Indicator null null null null null EWP and Fan
Over Temperature Warning null null null null null null
Audible alarm null null null null null null
Display dimmer null null null null null null
 Mounting position Engine bay Engine bay Vehicle Cabin  Engine bay Engine bay Vehicle Cabin
 Mounting options Built in Mounting holes Bracket supplied Universal 52mm gauge Built in Mounting holes Built in Mounting holes Verious Mounting Options supplied

 

User Reviews

  • Be the first to review this product.

Please Login to add your review.