The EWP®150 Alloy 12V is available for purchase in following options:
Muscle up your engine cooling system with the Davies Craig EWP®150 alloy Electric Water Pump and the LCD EWP®/Fan Digital Controller.
Like all EWP®s, this advanced unit is designed for remote mounting in the engine bay to satisfy those higher horsepower, turbocharged, supercharged and ‘worked’ engines which develop excessive heat & intercooler applications.
COMBO CONTENTS | |
PART DESCRPTION | UNITS |
EWP®150 Alloy |
1 |
EWP®/Fan Digital Controller & Mounting Plate + Bracket |
1 |
Sensor Thermal - coolant temp - ¼" NPT thread |
1 |
Adaptor - Nylon - In Line, 38mm (2 x 1/4" NPT) |
1 |
1/4" NPT Nylon - Bung | 1 |
Wiring Harness |
1 |
Hose Clamps |
4 |
SCREW - SELF TAP 8X3/8 BZ |
1 |
BLUE 6mm Ring Terminal | 1 |
TECHNICAL SPECIFICATIONS | ||||
EWP150 - ELECTRIC WATER PUMP | LCD CONTROLLER | |||
Operating voltage | 3V DC to 15V DC | Voltage range | 12V DC to 29V DC | |
Maximum current | 10A @ 13V | Display LCD size | 64.6mm (2.54”) x 55.6mm (2.19”) | |
Flow rate (max) | 162L/min (42.8 US gal/min) @ 13V DC | Maximum current | 12Amps | |
Operating temp. | -40° to 120°C (-40° to 248°F) | Warning alarm | High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit | |
Pump design |
Clockwise centrifugal with volute chamber |
Targeted (set) temperatures | Singular degrees from: 40°C (104°F)to 110°C (230°F) |
|
Pump weight | 1,170 grams (2.6 lb) | Memory | Set & targeted temperature | |
Pump material | Aluminium (Powder Coated) | Fan cut-in temp. | 3°C (5.4°F) above the targeted (set) temperature | |
Burst pressure | 500 kPa (72.5 psi) | Controller type | PCB with micro-processor | |
Seal | Ceramic face seal | Sensor type |
Thermister in housing |
|
Self Priming |
No, none of our pumps are self-priming |
|||
Fits hose size |
35mm to 51mm (1.38” to 2”) |
Overrun/ shutdown | -10°C (14°F) below set/target temperature or 3 minutes | |
Indicators | Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm) | |||
Internal Fitting | -Inlet & Outlet: -16AN ORB | Weight | 100 grams (3.5 oz) | |
Push-On fitting Size |
EWP Inlet & Outlet 38mm
|
Dimensions |
Length = 98mm (3.8") |
EWP & CONTROLLER INSTALLATION DEMONSTRATION
The compact EWP®150 alloy unit is manufactured with AN-16 ORB internal inlet and outlet fitting for neat, tight screw-in fitting applications. This rugged alloy hi-flow electric water pump is designed to complement or replace the engine’s existing mechanical water pump. This essential performance part increases power to
your vehicle’s drive wheels and improves coolant temperature control.
The EWP®150 is a universal, do-it-yourself, easy installation fitment to engines up to seven litres. By removing the parasitic power losses of belt-driven water pumps, the EWP®150 releases up to 10kW (13hp) of extra power, increased torque and fuel savings. Combine it with the LCD EWP®/Fan Digital Controller and the pump continues to run after you’ve switched off, eliminating “heat soak” and extending engine life.
The EWP®150 and LCD EWP®/Fan Digital Controller Combo Kit is the most economical way to increase horsepower and save on fuel consumption whilst caring for your engine.
EWP® INSTALLATION OPTIONS
Installing an EWP® as an AUXILIARY PUMP
EWP® INSTALLATION – disabling Mechanical water pump
In both these cases, the EWP® will pump past the impeller of the mechanical water pump.
Disengaged mechanical water pump (recommended)
Removed mechanical water pump (Ideal)
In most cases EWP® will be adequately supported by the radiator hose. Where mounting is required, the EWP® must be soft mounted to protect against vibration. For the EWP115, EWP130 and EWP150 Part #8700 Mounting bracket is recommended.
EWP® & FAN DIGITAL CONTROLLER
This LCD EWP® / Fan Digital Controller (Part #8002) is Australian designed and as part of this Australian manufacturing company’s continuous improvement program this advanced Digital Controller boasts a suite of enhancements.
The updated LCD Digital Controller how has two specific functions. This unique Controller will now manage the operation of the EWP® by varying the speed of the EWP® in response to the temperature of the engine and manage control of your electric engine fan. The Controller has a push-button on the facia panel that offers target temperatures Singular degrees from 40°C (104°F)to 110°C (230°F).
Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The LCD Digital Controller will now operate the engine’s electric fan automatically once the engine has reached +3c above the target temperature. A significant benefit too is the Controller allows the EWP® to run on after ignition shutdown to reduce heat soak. It is recommended that engine operational temperatures be checked with manufacturer.
Features
Black & White Numerical Screen
Celsius or Fahrenheit display option
Warning Alarms:
- Plus 10°C (14°F) set/target temperature
- Under temp 40°C after 5 mins
- Temp sensor error
- Over or under voltage
- EWP error
Select any set temp range from 40°C (104°F)to 110°C (230°F)
Set / targeted temperature memory
Override feature to assist bleeding EWP & fail safe
Input voltage display
Compatible with billeted style Electric Water Pumps
PRODUCT SELECTION GUIDE Electric Water Pump (EWP®) |
|||||||
APPLICATION |
PUMP MODEL |
PUMP ONLY | PUMP KIT | PUMP COMBO | |||
12V | 24V | 12V | 24V | 12V | 24V | ||
Engines up to 2.0L (Standard) |
EWP®80 | #8105 Nylon #8106 Flange #8109 Barb |
N/A | #8005 Nylon #8006 Flange #8009 Barb |
N/A | #8907 Nylon #8908 Flange #8919 Barb |
N/A |
Engines up to 2.0L - 3.5L (Standard) |
EWP®115 | #8125 Nylon #8140 Alloy |
#8126 Nylon #8141 Alloy |
#8025 Nylon #8040 Alloy |
N/A | #8930 Nylon #8950 Alloy |
N/A |
Engines up to 3.5L - 5.0L (Standard) |
EWP®140 | #8180 Alloy | #8181 Alloy | #8080 Alloy | N/A | #8990 Alloy | N/A |
Engines 5.0L or greater (Standard) Modified Engines Supercharged/Turbo, Drag Racing, 4WD, Off Road, Drifting & Speedway |
EWP®150 | #8160 Sliver #8165 Black |
#8161 Silver | #8060 Silver #8065 Black |
#8061 Silver | #8970 Silver #8975 Black |
#8971 Silver |
Intercooler (depending on capacity) |
EWP®115 | #8125 Nylon #8140 Alloy |
#8126 Nylon #8141 Alloy |
#8025 Nylon #8040 Alloy |
N/A | #8930 Nylon #8950 Alloy |
N/A |
EWP®140 | #8180 Alloy | #8181 Alloy | #8080 Alloy | N/A | #8990 Alloy | N/A | |
EWP®150 | #8160 Sliver #8165 Black |
#8161 Silver | #8060 Silver #8065 Black |
#8061 Silver | #8970 Silver #8975 Black |
#8971 Silver |
For further information, see Product Information
Yes, you can run 2 pumps in series, however I would look at using a thermal switch to control the flow of the second pump.
The use of a thermal switch will allow you to always have the additional flow needed and can assist is catching any overheating issues.